| Programme |
|
| 09 00h |
|
Opening
Catalina McGregor, Founder and UK GOV Deputy Champion Green ICT CIO/CTO Council, Office of HM Government CIO |
|
| 09 15 - 09 30 |
|
"State of the Market"
Review of Power, Cooling and Location Based on Research Findings
Steve Wallage, Managing Director, BroadGroup Consulting
|
|
| 09 30 - 10 45 |
|
Power and Cooling Design: Innovation Deep Dive
Chair: Alex Rabbetts, Managing Director, Migration Solutions
A rack full of blades can drive densities to 30kw or higher. Typical datacenters can support much less (10kw or even lower).
By designing for less dense systems we could support:
- lower power per system due to less restricted airflow
- lower cost per system
- higher operating temperatures
- resulting in more free cooling (ie more outside air cooling)
All of these deliver value to the end user. What are the tradeoffs and what is the most innovative design for low density?
Guest Speaker: Roy Zeighami, Principal Power & Cooling Architect, Hewlett Packard
Innovation in Containerization
The key concerns for any data centre are power availability and cooling reliability; how can containerized data centre design
address niche market requirements successfully?
Rod Evans, Managing Director, SGI
Building Green into Data Centre Design
Design is confronted by the need to reflect continuing shifts in how buildings are configured. Data centres will be launched
before the end of this year that are chiller less and cooling tower less with a significant reduction of air moving equipment.
Green design requirements are also expected to intensify as pressure for carbon reduction becomes mandatory. What will data
centre design look like in 5 years time?
John Berendzen, AIA, LEED AP, Fox Architects
|
|
| 10 45 - 11 10 |
|
Managing Power Consumption Efficiently and Effectively
Joe Polastre, Chief Technology Officer, Sentilla Corporation
|
|
|
| 11 40 - 12 40 |
|
Green Innovators: will future proofing work?
A high level of concern exists about the future impact of green regulations on data centre facilities.
In planning green initiatives how should the industry prepare – what innovations will offer the best medium term solutions?
Introduction by the Chair: Dr Ian F Bitterlin, Chief Technical Officer, Prism Power Ltd
Kate Craig-Wood, Managing Director, Memset Ltd
Miles Gray, Hardware Platform Architect, Department of Health Informatics Directorate
Michalis Grigoratos, Senior Design & Sustainability Consultant, Halcrow Yolles
Pip O Squire, MSc, DIC, BA (Hons) Oxon, CGeol, FGS, Engineering and Projects Director, Ark Continuity
|
| |
|
|
| 12 40 - 13 00 |
|
Presentation
Tony Day, Global Director Data Center Projects & Professional Services, APC by Schneider Electric
|
|
|
| 13 30 - 14 00 |
|
Lunch break special presentation:
BCS/Carbon Trust - Data Centre Cost Energy Simulator
Understanding energy and cost within your data centre using the BCS data centre simulator
Plus a live demo of the BCS tool in action helping to build the business cases for change
Zahl Limbuwala, Romonet
|
|
| 14 00 - 15 15 |
|
Natural Solutions for the Data Centre
Water, air, tidal waves, wind and other natural solutions are being launched – but will they bring cost effectiveness?
Chair: Marion Howard Healy, Associate Consultant, BroadGroup
Burton Hamner, Co-Founder & President, Hydrovolts
Greg Mason, Data Centre Specialist, Atlantis Resources Corporation
Rennie Dalrymple, Partner, Bruce Shaw Partnership
Donal Mac Nioclais, Commercial Development, Aquamarine Power
Maurice Julian, Data Centre Manager, HP (EDS) Wynyard
|
|
|
| 15 45 - 17 00 |
|
Strategies for Power and Cooling
Introduction by chair: Ashley R Davis, Managing Director, JPMorgan
Jim Smith, CTO, Digital Realty Trust
Lex Coors, Director of Engineering at Interxion HQ
Mees Lodder, Director, Kyoto Cooling
Rob Coupland, COO, TelecityGroup
|
|
| 17 00 - 17 40 |
|
International standards, benchmarks and regulation – the implications for power and cooling
Chair: Bernard Lecanu, Member of European Commission Green IT Group
Mark Acton, Data Centre Optimisation EMEA Lead, Dell
Roland Broch, Business Development, Datacenter Star Audit, eco - Verband der deutschen Internetwirtschaft e.V. |
|
| 17 40 |
|
Close of Conference |
|
|
|
|
|
|
|